Resetting the Datalogic Skorpio X3

SkorpioX3

There are several reset methods for the Skorpio X3.

A) A warm boot terminates an unresponsive application and clears the working RAM, but preserves the file system. The Registry is restored from persistent memory if available or returned to factory default.

B) A cold boot forces all applications to close, completely reinitializing the system. It clears the working RAM, but the file system is preserved. The Registry is restored from persistent memory.

C) A clean boot restores the Skorpio X3 to a clean configuration: both the Registry and the file system returns to a clean status that conforms to factory default.

 

Warm Boot

Cold Boot

Clean Boot

Registry

Restored from flash

Restored from flash

Clean configuration (no user config)

File System

Preserved

Preserved

Clean installation (no user files)

 

A) Warm Boot

To perform a warm boot, press and hold the following keys simultaneously:

Yellow function button + Blue function button + ESC key.

B) Cold Boot

To perform a cold boot, do the following steps:

1. Turn off the Skorpio X3 by pressing the ON/OFF Power button.

2. Pull the battery latch down and remove the battery pack.

3. Simultaneously press the SCAN key and the Reset button in the battery compartment.

4. Insert the battery pack.

5. Turn on the Skorpio X3 by pressing the ON/OFF Power button.

C) Clean Boot

To perform a clean boot, do the following steps:

1. Perform a Cold Boot (see Cold Boot)

2. Press and hold down the ‘Esc’ + ‘0’ keys simultaneously, promptly after resetting:

A dialog box will appear asking for confirmation. Press the Enter Key.